Product Details:
| Minimum Order Quantity | 1 Piece |
| Optical Type | Double Beam |
| Wavelength Range | 190-1100 nm |
| Instrument Type | Benchtop |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Measurement Mode | Absorbance, Concentration, Transmittance, Kinetics |
| Display Type | LCD |
| Brand | Systonic |
| Sample Holder | Standard Cuvette |
| Model No / Item Code | S-919 |
| Usage Area | Chemical Lab, Academic Lab, Pharma Lab, Environmental Lab, Clinical Lab, Food Lab |
| Interface | USB |
| Photometric Range | 0-200%T, -4 + 4A, 0-9999C |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
| Detector | Silicon Photodiode |
| Grating | 1200 Lines/mm |
| Baseline Flatness | +- 0.001A |
| Data Output Port | USB Port |
| Display | Graphical Display |
| Noise | +- 0.001A |
| Cell Holder | 2 |
| Printer Port | Parallel Port |
| Wavelength Repeatability | 0.2 nm |
| Material | Plastic |
| Wavelength Accuracy | +- 0.3 nm |
| Stray Light | < 0.05% @220 nm & 360 nm |
| Stability | 0.001A/h @500 nm |
| Weight | 26 KG |
| Band Width | Variable 0.5/1.0/2.0/4.0/5.0 nm |
| Product type | Systonic Spectrophotometer |
| Net weight | 26 kg(approx. ) |
| Dimensions(lwh) | 630 x 430 x 206 mm (LXBXH) |
Advance Double Beam UV-VIS Spectrophotometer Variable bandwidth
We are mainly looking for dealer query only from export Double Beam UV VIS Spectrophotometer Variable Bandwidth based instrument designed for quick and accurate spectrophotometric analysis of any concentration. It operates at a wavelength range of 190 nm to 1100 nm. The use of diffraction grating in the monochromator produces a linear spectrum. The grating having very high resolution of 1200 lines/mm ensures a narrow bandwidth. The instrument output is available in terms of % transmission (%t), absorbance (abs. ), & concentration (conc. ). The instrument is suitable for clinical lab applications, pharmaceutical and biochemica, as well as routing applications such as quantitative analysis, kinetics, wavelength scan, multi-wavelength and dna/protein analysis. The instrument has sample storage memory and printer output port for printing of data with any dot matrix printer. The pc can be connected using the usb interface. Provision for 2 position cell changer with 10 mm path-length cuvette is provided.This product is also known as Spectroscopic Equipment.
Features:-
1. Maximum of 9 wavelength & 2 sample can be measured at one time.
2. Optimized optics and large-scale integrated circuits design light source and receiver from world famous mearurement methods all add up to high performance and reliability.
Technical Specification:-
|
Model |
919 |
|
Optical System |
Double Beam (1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100 nm |
|
Mode |
Basic/ Quantitative/Wavelength Scan/DNA Protein Test/Kinetics/Multi Wavelength |
|
Scanning Speed |
Fast/Medium/Low |
|
Spectral Bandwidth |
0.5/1.0/2.0/4.0/5.0 nm |
|
Wavelength Accuracy |
≤ ± 0.3 nm |
|
Wavelength Repeatability |
0.2 nm |
|
Photometric Accuracy |
± 0.3% T |
|
Photometric Repeatability |
± 0.2%T |
|
Light Source |
Deuterium & Tungsten Halogen Lamp |
|
Display |
Graphic LCD (320X240 Dots) |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
2 Cell Holder |
|
Weight |
26 KG (Approx.) |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Optical Type | Double Beam |
| Wavelength Range | 190-1100 nm |
| Instrument Type | Benchtop |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Measurement Mode | Transmittance, Absorbance, Kinetics, Concentration |
| Display Type | LCD |
| Brand | SYSTONIC |
| Cell | 2 Cell Holder |
| Sample Holder | Standard Cuvette |
| Model No / Item Code | S-927 |
| Color | White |
| Usage Area | Chemical Lab, Environmental Lab, Academic Lab, Clinical Lab, Pharma Lab, Food Lab |
| Interface | USB |
| Photometric Range | 0-3.000 Abs |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
| Grating | 1200 Line |
| Detector | Silicon Photodiode |
| Data Output Port | USB |
| Display | Graphic LCD |
| Power Supply | 220 V AC |
| Warranty | 1 Year |
| Power Requirement | 220 V AC |
| Weight | 26 Kg. |
| Band width | 1nm |
Microprocessor Double Beam UV-VIS Spectrophotometer
Product Details:-
Minimum Order Quantity1 Piece Wavelength reproducibility0. 2 nm Photometric accuracy+ 0. 3 % T,Material PLASTIC Wavelength range190-1100 nm Wavelength accuracy+0. 3 nm Display Graphical LCD Product type Spectrophotometer Brand Systonic ModelS-927 Wavelength Range (nm)190-1100 nm Application Industrial Use
We are mainly looking for dealer query only from export. we are accomplished leading manufacturers and suppliers of an engineered range of micro processor Double Beam UV VIS Spectrophotometer. Our products are known for their durability, versatility, ruggedness, easy operations, longer lives and perfect accuracy in determining absorbency, % transmission and concentration of liquid. Some other features are: Capable of covering 190 to 1100 nm 8 position cuvette holder USB computer interface High wavelength precision Great & compact shapes Perfectly stability and accuracy Supreme quality Standard market rates.
Features:-
(A)Data output can be obtained via a printer port and USB interface.
(B) PC Controller measurement can achieved for more accurate and flexible requirement.
Technical Specification:-
|
Model |
S- 927 |
|
Optical System |
Double Beam (1200 Lines/mm Grating) |
|
Scanning Speed |
Fast/Medium/Low |
|
Spectral Bandwidth |
1 nm |
|
Wavelength Accuracy (Full Wavelength Range) |
≤± 0.1nm (656.1nm D2); ≤± 0.3nm |
|
Wavelength Repeatability |
± 0.1nm |
|
Wavelength Resolution |
0.1 nm |
|
Keyboard |
Membrane Type |
|
Baseline Flatness |
± 0.001A |
|
Interface |
USB Port (PC) and Parallel Port (Printer) |
|
Light Source |
Deuterium & Tungsten Halogen Lamp |
|
Wavelength Setting |
Auto |
|
Photometric Mode |
T.A.C.E. |
|
Display |
Graphic LCD (320X240 Dots) |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
2 Cell Holder |
|
Weight |
26 KG (Approx.) |
Additional Information:
Product Details:
| Minimum Order Quantity | 01 Piece |
| Optical Type | Double Beam |
| Wavelength Range | 190-1100 nm |
| Instrument Type | Benchtop |
| Spectral Bandwidth | 1 nm |
| Measurement Mode | Absorbance, Transmittance, Concentration |
| Display Type | TFT Color |
| Usage Area | Pharma Lab |
| Interface | RS232, USB |
| Power Supply | 230 V AC |
• High quality flashing xenon lamp which can start to test directly without preheating
•Powerful functions like Photometric measurement, Quantitative measurement, Kinetics, Spectrum Scan, DNA/Protein test, Multiwavelength test, etc
•In-house massive memory is capable of saving up to 1024M for test data & working curves
• Supports USB storage, The USB port can be used for data transfer, which is easily exported to Excel for further processing, analysis and storage
•Large sample chamber can accommodate 5-100mm cuvettes of all kinds. Provide at Extra cost
•Extensive accessories are optional, such as auto 8-cell holder, pelttier/sipper system, 21 CRR compliant
Technical Specification:
Optical System:Double Beam, Grating 1200 lines/mm
Wavelength Range :190 nm-1100nm
Spectral Bandwidth :1 nm
Wavelength Accuracy :±0.1nm @ 656.1nm, ±0.3nm@all
Wavelength Repeatability: ≤0.1nm
Photometric Accuracy: 0.2%T(0~100%T),±0.002A(0-0.5A),±0.004A(0.5-1A)
Photometric Repeatability :≤0.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range :0-200%T, 0.3~3A, 0-9999C (0-9999F)
Stray Light :≤0.03%T@220nm, 360 nm
Stability :±0.0005A/h@500nm
Baseline Flatness: ±0.001A
Noise: 0.0005A@500nm
Work Mode: T%, Abs, Conc, Reflactance, E,
Scanning Speed :Hi, Med, Low (Max. 3000nm/min)
Wavelength Setting: Auto
Display: 7” TFT Color Screen
Light Source :Hamamatsu Xenon Lamp
Detector: Imported Silicon Photodiode
Cuvette Holder: 10mm single hole cell holder
Output :USB drive, USB host,
RS232
Power :AC 220V/50Hz or AC 110V/60Hz
Shipping Size :810*660*390mm
Gross Weight: 27kg
Standard Accessaries: 10mm glass cuvette x 4, 10mm quartz cuvette x2, Power cord, User’s Manual, PC software
Additional Information: