Product Details:
Minimum Order Quantity | 01 Piece |
Model Name/Number | COD Digestion Apparatus S-9312 |
Color | white and blue |
Power Source | 230V AC |
I Deal In | New Only |
Brand | SYSTONIC |
Heating Temperature | 150 DegreeC +- 1 DegreeC |
Diameter Reaction Vessels | 36mm |
Country of Origin | Made in India |
COD Digestion Apparatus with Auto Time Control & Microprocessor Based PID Temperature Controller S- 9312
In wastewater treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water.
Features: -
Ø To Determination of chemical oxygen demand
Ø Solid state block heated unit with provision for samples to be digested at a time.
Ø 36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Ø Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
Ø To work on 220/230 Volts AC Supply.
Technical Specifications:-
Block Dimension:- 200 X 100 X 80 (L X W X H in mm)
No. of Cavity:- 12
PID Temp. Controlled & Auto Timer Control:- Ambient +5° C to150° C
Additional Information:
Product Details:
Minimum Order Quantity | 01 Piece |
Model Name/Number | COD Digestion Apparatus S-9306 |
Power Source | 230V AC |
I Deal In | New Only |
Brand | SYSTONIC |
Minimum Order Quantity | 01 |
Block Dimension | 100X100X80 |
Heating Rating | 150 DegreeC +- 1 DegreeC |
Country of Origin | Made in India |
In wastewater treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water.
Features: -
Ø To Determination of chemical oxygen demand
Ø Solid state block heated unit with provision for samples to be digested at a time.
Ø 36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Ø Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
Ø To work on 220/230 Volts AC Supply.
Technical Specifications:-
Block Dimension (L X W X H) |
No. of Cavity |
PID Temp. Controlled & Auto Timer Control |
100 X 100 X 80 mm |
6 |
Ambient 5°Cto150°C |
Additional Information:
Product Details:
Minimum Order Quantity | 01 Piece |
Model Name/Number | COD Digestion Apparatus S-9315 |
Color | white and blue |
Power Source | 230V AC |
I Deal In | New Only |
Brand | SYSTONIC |
Minimum Order Quantity | 01 |
Diameter Reaction Vessels | 36mm |
heating Temperature | 150 DegreeC +- 1 DegreeC |
Country of Origin | Made in India |
In wastewater treatment, the Chemical Oxygen Demand (COD) is an important measurement for the amount of oxygen that is required to break down pollutants (organic substances) in water.
Features: -
Ø To Determination of chemical oxygen demand
Ø Solid state block heated unit with provision for samples to be digested at a time.
Ø 36 mm diameter reaction vessels with 20 ml sample size to heat at temperatures of 150°C ± 1° C.
Ø Supplied with air condensers, glass reaction vessels. Samples after being digested for 2 hours can be analyzed using calorimeter or conventional titration method.
Ø To work on 220/230 Volts AC Supply.
Technical Specifications:-
Block Dimension (L X W X H) |
No. of Cavity |
PID Temp. Controlled & Auto Timer Control |
200 X 200 X 80 mm |
15 |
Ambient 5°Cto150°C |
Additional Information: